Signal Control Loop Sensor
Fire
Alarm Protectors FA 12V B and 30VB are surge protectors for “B” type zones
or loops of either 12-volt or 24-volt. Protectors are 3-stage with primary
and secondary protection that will greatly reduce false alarms caused by
lightning and will protect the equipment. Units are encapsulated with a
heat dissipating epoxy, which greatly enhances component performance. Specifications
for Fire Alarm Zone Protectors •
Connection: Terminal
Board •
Power Dissipation: 2,000,000
Volt Amps / Line
2 Pair (“A”
Zone) •
UL 497 listed •
Tested to
ANSI/IEEE B-3 Impulse
• Technology: Hybrid
Circuit
Multi-Stage
Design
Full
Heat sinking
• Response: < 5 Nanoseconds
• Operating Temperature: -400C
- +850C
• Operating Environment Weather
Proof
• Voltage: Voltage
Sensitive
• Current: Non
Load-Bearing
No
Follow -On Current
• Clamping Point: 15
or 30 or 64 Volts
4,000,000
Volt Amps /
Line
Pair
• Lines Protected: l
Pair (“B” Zone)
S
Fire Alarm Class A is 2 Pair, Class B is 1 Pair FA 12VA 12V”A”
Zone Protector -
2 Pair FA 12V B 12V”B” Zone Protector - 1 Pair FA30VA 24V”A” Zone Protector - 2 Pair FA30VB 24V”B” Zone Protector
– 1 Pair FA30VB-BH 24V+ 3 amps ”BH” Bells
Horns - 1Pair FA60VB 34.8V+”B” Zone
Protector -1 Pair FA60VB-NC 34.8V+ 3amps ”B-NC” Bells
Horns – 1 Pair .
In-line Series Hybrid Three Stage AC Surge Suppressor
This Unique Product is designed to provide superior
transient voltage surge protection & noise reduction for Branch
Circuits, Fire Alarms, PLC, NC/CNC, Controls, Card Access, Gate Access,
Telemetry, (2)units in a 120/120 240 single phase application for PLC or
Computer related PC board power supply drawing no more the 20 amps per
line. This unit will eliminate a
high degree of noise coming in the AC power, caused by HVAC, Pumps, Motors
and other noisy equipment that can cause false alarms especially on Fire
Alarm panels, or harmful effects affecting the performance of the PC board. Maximum Operating Voltage 135 Volts Follow on current none Circuit Breaker 20
amps Connection In-Line
series Hardwired Operating Temperature -32ito 85i C Maximum Surge Current (8 x 20us) 300KVA Maximum Surge Voltage (1.2 x50us) 20K Volts TVSS Device UL File E121637 UL 1449 RVSS Rating 330 Volts L/N,
N/G, L/G Clamping Point 138
Volts RMS, 198V Peak Clamping Response Time <5 nanoseconds Maximum Line Amperage 20 Amps @120 VAC 45/60Hz Active Filtering Dual-Full
P-N,N-G Response 1Pico Three Stage Filter 40dB
down-10KHz to 10 Mhz Power Dissipation (8x 20us) 3000
Joules, or 12,000KVA Failure Mode Fails
Safe (open) UL 1449 2nd edition Dimensions Depth:
2.5”, Width: 4.5” Length 5” Mounting (4) .5” tabs & (2) ½” nipples Installation P/N/G(3)wire
Line in,(3)wire load out Weight Approximately
2.5 Pounds 6000V @ 3000amps 8
x20 us 220V Peak P/N, ANS/IEEE Cat. B3 265VPK
P/G, 207 VPK N/G
120HWCP20CB
Specifications – Operating
Surge Suppressors Click
to Index Click to Page 18 Click to Page 20 PLC Page 19
Need some help click on me!